Skip to content

Units and standard conditions

Canonical units

Everything is converted to one unit per quantity before it is calculated.

Quantity Canonical unit
Gas volume Sm³, at 15 °C and 101.325 kPa (ISO 13443)
Liquid volume m³
Mass tonnes

Gas volumes and standard conditions

A gas volume means nothing without the temperature and pressure it is quoted at, because gas expands when warm and compresses under pressure.

  • The oil industry's standard cubic foot (scf) is quoted at 60 °F and 14.696 psia.
  • The standard cubic metre FieldTruth uses is quoted at 15 °C and 101.325 kPa.

These are close but not identical. 60 °F is 15.56 °C, so a standard cubic foot of gas at 60 °F occupies slightly less space when cooled to 15 °C. FieldTruth converts properly:

\[ 1 \text{ scf} = 0.028316846592 \text{ m}^3 \times \frac{288.15}{288.7056} = 0.0282624 \text{ Sm}^3 \]

Ignoring the correction is an error of about 0.2%, small, systematic and always in the same direction, which is the kind of error an audit finds.

Recognised units

Written as Means In Sm³ or m³
Sm3, sm3, SM3 Standard cubic metre 1
scf Standard cubic foot 0.0282624
Mscf, mscf, MSCF Thousand scf 28.2624
MMscf, mmscf Million scf 28,262.4
bbl US barrel 0.158987294928 m³

Rates such as MMscfd are converted to volumes over the row's period.

M means a thousand

In oil and gas, M means a thousand (from the Roman numeral) and MM means a million. A column headed Mscf read as millions is a thousandfold error. FieldTruth's quality checks look specifically for this, typically when flared gas comes out larger than gas produced.

The original value is kept

Every observation stores the value and unit exactly as they appeared in the source file, beside the converted value, and records each conversion step. Once the original is discarded, a wrong conversion and a right one look identical, so it is never discarded.