Global warming potentials, and why there are two¶
What a GWP is¶
A global warming potential (GWP) is the number you multiply a tonne of a gas by to express it as tonnes of CO₂ equivalent. It compares how much heat one tonne of the gas traps over a chosen period of time with how much one tonne of carbon dioxide traps over the same period. See CO₂ equivalent for how it is used.
Two choices determine the value.
The time horizon. Methane traps a great deal of heat but breaks down in about twelve years, while carbon dioxide lasts for centuries. Measured over twenty years, methane looks very powerful compared with CO₂; measured over a hundred years, much of methane's effect has already passed and it looks less so. The same gas therefore has a larger 20-year GWP than 100-year GWP.
The Assessment Report. The IPCC updates GWPs with each Assessment Report as the science improves. See The IPCC.
| Gas | AR5, 100 years | AR6, 100 years | AR6, 20 years |
|---|---|---|---|
| Methane (fossil), CH₄ | 28 | 29.8 | 82.5 |
| Nitrous oxide, N₂O | 265 | 273 | 273 |
Two bases are in force in Nigeria¶
This is the single easiest place to produce a confidently wrong number under the Nigerian regime, so it is worth reading slowly.
For the emissions inventory, the Commission's own submission workbook fixes the factors at AR5, 100 years: methane 28 and nitrous oxide 265. They are written into the workbook's header and it totals against them. The operator does not choose.
For energy intensity, Appendix D of the 2022 methane guidelines specifies a methane GWP of 82.5, the AR6 20-year value.
These are different questions. The inventory asks how much each operator contributed to long-term warming. The energy intensity measure is designed to reward cutting methane quickly, so it uses the 20-year horizon, where methane's effect is largest.
What goes wrong if you mix them¶
Suppose a facility emitted 100 tonnes of methane.
| Basis | Methane GWP | Methane as CO₂e |
|---|---|---|
| AR5, 100 years (inventory) | 28 | 2,800 t |
| AR6, 20 years (energy intensity) | 82.5 | 8,250 t |
Using the inventory basis for the energy intensity figure understates it by roughly a factor of three. Using the 20-year basis in the inventory overstates the inventory by the same factor. Either mistake produces a number that looks perfectly reasonable on the page.
What FieldTruth does¶
- Every calculation run records its GWP basis, and the basis is printed next to every total on every report. A total without its basis is not a fact.
- The inventory basis is taken from the rule pack, which transcribes it from the Commission's workbook, so it cannot be set to the wrong value by accident.
- The basis is part of the run's manifest hash, so two runs that differ only in their GWPs can never be mistaken for one another.