Skip to content

How emissions are calculated

FieldTruth's calculation engine is a pure function: the same data, method, factors, rules and assumptions always give the same result, to the last digit. Nothing in it reads the clock, the network or a model. This page sets out every path a number can take.

Which method applies

For each observation in the approved dataset:

Observation Method Result state at best
Measured flare volume Flare mass balance Calculated, if the destruction efficiency was measured; otherwise estimated
Measured vent volume Vent mass balance Calculated
Fuel gas volume IPCC stationary combustion factors Estimated
Oil production, gas production, gas processed IPCC production factors Estimated

Where a flare or vent volume was measured, the IPCC production factor for flaring or venting is not applied as well. Applying both would count the same gas twice.

A result can never have a better state than its inputs. See source states.

Constants

Constant Value Source
Standard condition 15 °C, 101.325 kPa ISO 13443
Molar volume of an ideal gas at that condition 23.6448 Sm³ per kmol R × T / P
Molar mass of methane, CH₄ 16.043 kg per kmol
Molar mass of carbon dioxide, CO₂ 44.009 kg per kmol
One standard cubic foot (60 °F, 14.696 psia) 0.0282624 Sm³ Converted to 15 °C

Flare mass balance

Gas sent to a flare is mostly methane. The flare burns a fraction of it, the destruction efficiency η, and each molecule of methane burned becomes one molecule of carbon dioxide. The rest escapes as methane.

\[ n_{\text{CH}_4} = \frac{V \times x_{\text{CH}_4}}{V_m} \]
\[ m_{\text{CH}_4} = n_{\text{CH}_4} \times (1 - \eta) \times M_{\text{CH}_4} \qquad m_{\text{CO}_2} = n_{\text{CH}_4} \times \eta \times M_{\text{CO}_2} \]

where V is the flared volume in Sm³, x is the methane mole fraction, V_m is the molar volume and M is the molar mass.

Worked example

A flare handles 10 MMscf in a month. The gas is 85% methane. The efficiency is assumed at 98%.

Step Calculation Result
Volume in Sm³ 10,000,000 scf × 0.0282624 282,623.5 Sm³
Methane, kmol 282,623.5 × 0.85 ÷ 23.6448 10,159.9 kmol
Methane escaping 10,159.9 × 0.02 × 16.043 ÷ 1000 3.260 t CH₄
CO₂ formed 10,159.9 × 0.98 × 44.009 ÷ 1000 438.19 t CO₂
CO₂e (AR5, 100 years) 3.260 × 28 + 438.19 529.5 t CO₂e

Because the efficiency was assumed, both lines are estimated, and each carries the note that it reports the regulatory floor rather than measured performance.

If the flare was actually running at 92%, the methane escaping is 10,159.9 × 0.08 × 16.043 ÷ 1000 = 13.04 t, four times as much. This is why an assumed efficiency is labelled as such.

Vent mass balance

Vented gas is not burned, so all of its methane reaches the atmosphere.

\[ m_{\text{CH}_4} = \frac{V \times x_{\text{CH}_4}}{V_m} \times M_{\text{CH}_4} \]

The same 10 MMscf, vented instead of flared: 10,159.9 kmol × 16.043 ÷ 1000 = 163.0 t CH₄, which is 4,563.9 t CO₂e. Venting the gas has almost nine times the climate impact of flaring it at 98%, which is why the Commission prohibits cold venting without a waiver.

Stationary combustion of fuel gas

Fuel gas burned in turbines, heaters and engines uses the IPCC default factors for natural gas in the energy industries (2006 Guidelines, Volume 2, Chapter 2, Table 2.2). The factors are published per unit of energy, and operators meter volume, so a net calorific value bridges them.

Quantity Value
Net calorific value used 32.568 GJ per 1000 Sm³, derived from 48.0 TJ per Gg (IPCC Table 1.2) at the density of methane
CO₂ 54,300 to 58,300 kg per TJ
CH₄ 0.3 to 3 kg per TJ (IPCC default 1)
N₂O 0.03 to 0.3 kg per TJ (IPCC default 0.1)

Worked example

2.5 million Sm³ of fuel gas, low bound:

Step Calculation Result
Energy 2,500 thousand Sm³ × 32.568 GJ ÷ 1000 81.42 TJ
CO₂ 81.42 × 54,300 ÷ 1000 4,421 t CO₂

Combustion results are always estimated, however well the fuel gas was metered: the meter is measured, but the factor is a published average for an unspecified burner.

Rich gas carries more energy

The calorific value assumes gas that behaves like methane. Associated gas with more ethane and propane carries more energy per cubic metre, so the default understates combustion CO₂ for rich gas. An operator with a gas analysis should expect this figure to be conservative on the low side.

IPCC production factors

Sources without a measured volume use the IPCC Tier 1 factors for oil and gas operations in developing countries (2006 Guidelines, Volume 2, Chapter 4, Table 4.2.5), applied to production:

\[ m = A \times EF \]

where A is the activity, such as thousand m³ of oil produced, and EF is the factor at the bound chosen for the run: low, midpoint or high. See Emission factors for the table.

Converting to CO₂e

Each species' mass is multiplied by its global warming potential on the basis in force (AR5, 100 years, for the Nigerian inventory: CH₄ 28, N₂O 265). NMVOC is reported as a mass and not included in the total. See GWPs.

Periods that straddle a factor change

If an emission factor set changes on a date inside the reporting period, the period is split at that date and each part uses the factor that was in force. Using the new factor for the whole period would produce a plausible total that no audit could reproduce.

Known limitations of the current method

These are stated here rather than left for a reviewer to discover.

  • Flaring CO₂ counts the methane only. The flare mass balance converts methane to carbon dioxide. The ethane, propane and heavier hydrocarbons in associated gas also burn to carbon dioxide and are not yet included, so flaring CO₂ is understated for rich gas. Methane, the quantity this regime is about, is unaffected.
  • CO₂ already in the gas is not counted. Carbon dioxide present in produced gas and released by venting or passed through a flare is not yet added.
  • Uncertainties are combined as independent. See Uncertainty.

A full gas composition input, which would close the first two, is on the roadmap.