Data quality
Before anything is calculated, every dataset is checked against thirteen
rules. Each finding is raised against the row that caused it, with the
context needed to judge it.
Severities
| Severity |
Meaning |
| Blocker |
The dataset cannot be approved until this is resolved |
| High |
Very likely an error; needs a decision with a reason |
| Medium |
Often an error; worth checking |
| Low |
Not an error; information that matters for the inventory |
The rules
Blockers
| Rule |
What it catches |
Why it blocks |
| Negative volume |
A volume below zero |
Either the sign convention is inverted or a correction was entered as a reading, and the two need different treatment |
| Same source, parameter and period twice |
Duplicate rows |
Both would be counted, doubling the total with nothing on screen to show it |
| Overlapping periods on one source |
Two rows covering some of the same days |
The shared days would be counted twice |
| Synthetic data in a dataset |
Demonstration rows |
Demonstration data must never reach a filing |
| No stated basis |
A row whose source state is unknown |
Nothing can be said about a number with no basis |
| Row falls outside the reporting period |
A date outside the period |
It would be counted in a period it does not belong to |
High
| Rule |
What it catches |
| Flared volume exceeds gas produced |
More gas flared than produced. Almost always a unit mismatch, typically Mscf read as MMscf, a thousandfold error |
| Far from this source's own history |
A reading more than five times above, or below a fifth of, the median of this source's own history, once it has at least four earlier periods. Either a real event worth reporting or a transcription error |
| Gap in coverage |
Days in the period no row covers. Emissions on those days are not zero, they are unknown |
Medium
| Rule |
What it catches |
| Zero recorded while the facility produced |
A flare or vent reading of exactly zero for a full period on a producing facility, usually a meter that was not read |
| Implausible for the period length |
An implied daily rate no upstream facility sustains, usually a rate entered as a total or the wrong unit |
Low
| Rule |
What it catches |
| Material source not metered |
A source that moves the total is estimated. Not an error; it is what stands between this inventory and Tier 3 |
| Gas composition will be needed |
Measured flare or vent volumes need a methane content, which the run will ask for |
Disposing of a finding
A reviewer resolves each finding by choosing a disposition and writing a
reason:
| Disposition |
Use when |
| Corrected |
The data was wrong and has been fixed |
| Accepted |
The data is right, and the finding describes something real, such as a genuine upset event |
| False positive |
The rule fired on data that is fine |
| Superseded |
A replacement dataset takes its place |
Two rules are enforced:
- Every disposition needs a reason. Clearing a finding with no
explanation is how a check becomes a rubber stamp. The trail of who
decided what, and why, is part of the evidence.
- A blocker cannot be accepted. Correct the data and check again, or
supersede the dataset.
Approving the dataset
A reviewer approves the dataset once no blocker is open. Approval
freezes it: its contents are fingerprinted, and that fingerprint is pinned
into every run calculated from it. A dataset with an open blocker cannot be
calculated from, and a run that was never approved cannot be issued.