Emission factors and their sources¶
Every emission factor in FieldTruth lives in a versioned, cited factor pack, never in code. A factor written into application logic cannot be versioned, cited or superseded on a date, and each of those is something an auditor will ask about.
The pack in use¶
IPCC 2006 Tier 1, developing countries and economies in transition, version 1.1.0.
- Fugitive, venting and flaring factors: 2006 IPCC Guidelines for National Greenhouse Gas Inventories, Volume 2 (Energy), Chapter 4, Table 4.2.5.
- Stationary combustion factors for fuel gas: Volume 2, Chapter 2, Table 2.2.
Each factor carries its own citation, because one pack draws on two tables and attributing a number to a table it is not in is worse than giving no citation at all.
The factors¶
Values are in gigagrams (thousand tonnes) per unit of activity, low to high.
| Factor | Activity unit | CH₄ | CO₂ | NMVOC | N₂O |
|---|---|---|---|---|---|
| Oil production, fugitive, onshore | 10³ m³ oil | 1.5×10⁻⁶ to 6.0×10⁻² | 1.1×10⁻⁷ to 4.3×10⁻³ | 1.8×10⁻⁶ to 7.5×10⁻² | |
| Oil production, fugitive, offshore | 10³ m³ oil | 5.9×10⁻⁷ | 4.3×10⁻⁸ | 7.4×10⁻⁷ | |
| Oil production, venting | 10³ m³ oil | 7.2×10⁻⁴ to 9.9×10⁻⁴ | 9.5×10⁻⁵ to 1.3×10⁻⁴ | 4.3×10⁻⁴ to 5.9×10⁻⁴ | |
| Oil production, flaring | 10³ m³ oil | 2.5×10⁻⁵ to 3.4×10⁻⁵ | 4.1×10⁻² to 5.6×10⁻² | 2.1×10⁻⁵ to 2.9×10⁻⁵ | 6.4×10⁻⁷ to 8.8×10⁻⁷ |
| Heavy oil, fugitive | 10³ m³ oil | 7.9×10⁻³ to 1.3×10⁻¹ | 5.4×10⁻⁴ to 9.0×10⁻³ | 2.9×10⁻³ to 4.8×10⁻² | |
| Heavy oil, venting | 10³ m³ oil | 1.7×10⁻² to 2.3×10⁻² | 5.3×10⁻³ to 7.3×10⁻³ | 2.7×10⁻³ to 3.7×10⁻³ | |
| Gas production, fugitive | 10⁶ m³ gas | 3.8×10⁻⁴ to 2.4×10⁻² | 1.4×10⁻⁵ to 1.8×10⁻⁴ | 9.1×10⁻⁵ to 1.2×10⁻³ | |
| Gas production, flaring | 10⁶ m³ gas | 7.6×10⁻⁷ to 1.0×10⁻⁶ | 1.2×10⁻³ to 1.6×10⁻³ | 6.2×10⁻⁷ to 8.5×10⁻⁷ | 2.1×10⁻⁸ to 2.9×10⁻⁸ |
| Gas processing, fugitive | 10⁶ m³ gas | 4.8×10⁻⁴ to 1.1×10⁻³ | 1.5×10⁻⁴ to 3.5×10⁻⁴ | 2.2×10⁻⁴ to 5.1×10⁻⁴ | |
| Well drilling, flaring and venting | 10³ m³ oil | 3.3×10⁻⁵ to 5.6×10⁻⁴ | 1.0×10⁻⁴ to 1.7×10⁻³ | 8.7×10⁻⁷ to 1.5×10⁻⁵ | |
| Well servicing, flaring and venting | 10³ m³ oil | 1.1×10⁻⁴ to 1.8×10⁻³ | 1.9×10⁻⁶ to 3.2×10⁻⁵ | 1.7×10⁻⁵ to 2.8×10⁻⁴ | |
| Fuel gas combustion | 10³ Sm³ gas | 9.8×10⁻⁹ to 9.8×10⁻⁸ | 1.77×10⁻³ to 1.90×10⁻³ | 9.8×10⁻¹⁰ to 9.8×10⁻⁹ |
Why ranges, and why you choose¶
The IPCC publishes most of these as a range, because a Tier 1 factor describes a global population of facilities. For onshore oil fugitives the top of the range is forty thousand times the bottom. FieldTruth keeps both ends, the run states which it used (low, midpoint or high), and every line records the choice. There is no silent default hidden in a calculation.
What is missing is missing¶
Where the IPCC gives "not determined", the factor is left out of the pack rather than set to zero. A calculation that needs it raises a factor unavailable exception naming exactly what was looked for, instead of quietly contributing nothing. N₂O, for example, is published only for flaring and combustion.
Versions and dates¶
Every pack has an effective window. A run records the pack's identifier, version and a fingerprint of its content. Reformatting the file does not change the fingerprint; changing a single digit of a factor does.
Rules about where factors may come from¶
FieldTruth's factors come from published, citable sources only. No factor ships without a citation, and none is tuned against the output of any commercial software.