Tier 1, Tier 2 and Tier 3¶
The IPCC describes three tiers, which are levels of rigour for calculating emissions. A higher tier needs better data and gives a number that says more about the specific facility. The Nigerian directive of 11 April 2026 requires Tier 2 or better from the third quarter of 2026 and a full transition to Tier 3 from January 2027.
The same question at three tiers¶
Take one question: how much methane did this flow station's flare emit last month?
Tier 1: a global average¶
Multiply a measure of activity by a default factor published by the IPCC.
Oil produced last month × the IPCC default for methane from flaring per unit of oil produced.
The flare is never looked at. The answer is what an average flare somewhere in the world would have emitted for that much oil. It is quick and needs almost no data, and its uncertainty is enormous.
Tier 2: specific to the gas, the technology or the country¶
Use factors or inputs that reflect this operation rather than a global average.
The measured volume of gas sent to the flare × the methane content of this gas × the fraction a flare fails to burn.
This is much better. It uses the actual flared volume and the actual gas composition. It still assumes how efficiently the flare burned, usually the 98% design figure.
Tier 3: measured at the facility¶
Use detailed, facility-level data, which for methane in practice means measurement.
The measured flared volume × the measured composition × the measured destruction efficiency, or a direct measurement of what leaves the stack.
Now the figure describes what this flare actually did. If the flare was running at 92% rather than 98%, Tier 3 sees it; Tier 2 does not, and would have understated the methane by a factor of four.
Summary¶
| Tier 1 | Tier 2 | Tier 3 | |
|---|---|---|---|
| Activity data | Production totals | Measured volumes | Measured volumes, at source |
| Factors | IPCC global defaults | Country, technology or gas specific | Measured or source-specific |
| What the answer describes | An average facility | A facility like this one | This facility |
| Typical uncertainty | Very large, sometimes several hundred per cent | Moderate | Small, and stated |
| Nigerian status | No longer sufficient from Q3 2026 | Required from Q3 2026 | Required from January 2027 |
What "transition to Tier 3" means in practice¶
Moving to Tier 3 is not a software switch. It is the gradual replacement of estimates with measurements, source by source: installing a meter on a vent line, taking a gas sample for analysis, measuring a flare's efficiency, surveying for leaks with a camera. Some sources will reach Tier 3 long before others.
That is why FieldTruth does not report a single "tier" for a whole facility. It records the state of every source, calculates what share of the material sources is actually measured, and ranks the remaining sources by how many tonnes they contribute. The source that moves the total most is the first one worth metering. See Compliance and Tier 3 readiness.
Tier 3, its equivalent, or other frameworks
The directive allows "IPCC Tier 3, its equivalent, or high-level measurement-based methods under other frameworks". The Oil and Gas Methane Partnership 2.0, run by the United Nations Environment Programme, is one such framework; its highest reporting level reconciles source-level estimates with independent site-level measurement. FieldTruth's source-by-source measured share is the same idea expressed in the IPCC's terms.